(click on images above to enlarge)
|
HÜRNER SPG 2000 and SPG 2000 Basic Report Generation Units for fast,
accurate monitoring and recording of weld values under DVS and other national
standards (WIS, INSTA, etc.). The Report Generation Units SPG 2000 and SPG
2000 Basic can be universally used with any mechanically operated butt-welding
machine and with all hydraulically operated machines from KWH Tech, as well as
with various other makes. With SPG 2000 / SPG 2000 Basic, it is possible to
capture all the data needed to evaluate the quality of a welding operation and to
transfer them to a printer, a PC with the Hürner DataWork software installed, or
to the internal micro-printer.
| SPG 2000 Technical Specifications |
| Input voltage | 100V - 260V |
| Input frequency |
40Hz - 80Hz |
| Weight approx. | 4kg |
| Dimensions | 24 x 200 x 250 mm |
| Box Protection | IP 54 |
| Technical |
- Easy to use with intuitive and structured user menus
- Multilingual menus and reports
- Film-protected alphanumeric keypad with welding process diagram
- PC interface (RS232), printer (Centronics)
- Report capacity: 1000 welding operations
- LED-lit display, 4 rows, 20 characters each
- Automatic auto-test after power-up
- Report configuration customizable
- Pressure sensor 100 bars or 250 bars, as selected
- Temperature sensor PT100 or PT1000, as selected
- LEDs to display welding progress
- Scanning pen, handheld scanner
- Micro-printer (SPG 2000 only)
|
| Data Recorded |
- Machine type and machine ID
- Cylinder
- Sensors
- Material
- Diameter, wall thickness, nominal pressure
- Angle (on workshop machines)
- Incremental number and weld number
- Commission number (32 characters)
- Welder ID (ISO standard)
- Date and time of day
- Ambient temperature
- Nominal and actual values of:
- Drag pressure
- Plate temperature (can be disabled)
- Build-up pressure
- Build-up time
- Heat soaking pressure
- Heat soaking time
- Change-over delay
- Joining pressure ramp
- Joining pressure
- Cooling time
|
| Monitoring functions |
- Build-up pressure
- Plate temperature
- Heat soaking pressure
- Heat soaking time
- Ramp
- Joining pressure
- Cooling time
- Power supply failure
- Ambient temperature
- Memory for reports
|
| Traceability (SPG 2000 only) |
- Pipe codes (max. 40 characters, ISO)
- Fitting code (26 characters, ISO)
- Weather (DVS)
- Additional data (max. 20 digits)
|
Downloads: