Recognition
by test welding
If all other information is unavailable, a test weld can be tried on the back of the component using a rod from the identified mixed bundle of plastic welding rods.
Method
1. Fit
the appropriate welding nozzle for the selected welding
rod to the LEISTER TRIAC hot air tool.
2. Set the welding temperature on the rotary
control according to the welding rod material to
be employed in the test (see table under Main
Welding. Allow the tool to attain the operating
temperature.
3. Scrape the surface in the area of the test to remove any contamination.
4. Feed the welding rod through the nozzle
and into contact with the surface of the component.
5. Following the technique described in Main
Welding operations, weld 2cm of the test
rod to the surface of the component.
6. Remove the welding tool from the rod and
then cut the rod approximately 2cm from the component
surface.
7. Allow the weld to cool and then try to pull the rod from the surface of the component. If it can be pulled from the component, repeat the test with a different rod. If it stays firmly in place, the component plastic has been positively identified.
|